OmniWire Pressure Guide Wire | Philips Healthcare (2024)

World’s first solid core pressure guide wire.1

With an all new workhorse design, only Philips OmniWire pressure guide wire combines confidence in wire performance with proven iFR outcomes and iFR Co-registration, making it easy to benefit from physiology throughout the case.2-4

OmniWire Pressure Guide Wire | Philips Healthcare (1)

Only OmniWire brings together:

Confidence in wire performance with its workhorse design

Learn more

Proven iFR outcomes

Learn more

Advances PCI guidance with iFR Co-registration

Learn more

Designed more like a contemporary workhorse guide wire

New design from tip-to-tail to improve navigation in complex anatomy.

The embedded conductive ribbons eliminate the need for a hollow hypo tube therefore making a larger solid core possible similar to the design of a workhorse guide wire.

  • New Nitinol distal core provides increased durability and shape recovery: ideal for use in multi-vessel disease and complex cases.
  • Unique solid core for improved torque, pushability and kink resistance.
  • Durable, integrated conductive bands for confidence during device delivery, reconnections and post-measurements.

OmniWire Pressure Guide Wire | Philips Healthcare (5)

*Proximal cross-sections. Not to scale, for illustration purposes only.

Nitinal distal core and integrated conductive bands

The Nitinol core is super elastic for durability and shape recovery. Useful for long multi-vessel procedures. Integrated conductive bands enable the back end to be a continuous piece with no joints, designed to reduce kinking, facilitate device loading, device delivery and easy reconnects.

OmniWire Pressure Guide Wire | Philips Healthcare (6)
OmniWire Pressure Guide Wire | Philips Healthcare (7)

Improved durability

OmniWire Pressure Guide Wire | Philips Healthcare (8)

Improves pushability

With proven outcomes, iFR is in a class of its own

iFR is the gold standard among resting indicesbacked by clinical outcomes that reduces patient discomfort, procedural time and cost.2,3,5 while providing advance guidance with co-registration for confidence in your treatment decisions.

OmniWire Pressure Guide Wire | Philips Healthcare (11)

iFR is validated in the largest physiology clinical outcomes studieswith data from over 4500 patients. 2,3

9.0 KB

iFR is recognized by all three key cardiovascular societies. It is the only resting index with a class IA recommendation by the ESC, designated as “definitely beneficial” by SCAI, and included in both the ACC

AUC and NCDR.6-9

102.0 KB

Only iFR has co-registration for advanced physiologic guidance

iFR is the leading hyperemia-free physiologic index for measuring pressure in diagnostic and interventional procedures. Only offered by Philips, iFR is an evidence-based methodology that improves outcomes, saves time, and reduces patient discomfort. 5,10,11

iFR Co-registration maps the physiologic measurements, directly onto the angiogram enabling more complete procedural guidance.

• Mapping of physiologic pressure drops onto the angiogram to better discern focal, serial or diffuse disease

• Precise lesion severity, location and length assessment

• Make length measurements without a cumbersome pull back device

• Physiologic impact of a virtual stent

OmniWire Pressure Guide Wire | Philips Healthcare (14)

Plan your procedure with physiologic guidance.

iFR Co-registration* is available on Philips IntraSight intervention applications platform.

* Co-registration tools available within IntraSight 7 configuration via SyncVision

OmniWire Pressure Guide Wire | Philips Healthcare (15)

Resources

    OmniWire Pressure Guide Wire | Philips Healthcare (25)

    OmniWire data sheet (1.15MB)

    OmniWire Pressure Guide Wire | Philips Healthcare (26)

    OmniWire brochure (1.06MB)

    Indications for use:

    The OmniWire pressure guide wire is indicated for use to measure pressure in blood vessels, including both coronary and peripheral vessels, during diagnostic angiography and/or any interventional procedures. It can also be used to facilitate the placement of catheters as well as other interventional devices in coronary and peripheral vessels. Blood pressure measurements provide hemodynamic information for the diagnosis and treatment of blood vessel disease. The device is indicated for patients undergoing diagnostic angiography and/or percutaneous interventions in the coronary and peripheral vessels. iFR has been FDA cleared for ischemia testing using proven dichotomous cut-point, 0.89.

    Ordering information

    Order number

    Product name

    Size

    Tip shape

    89185

    OmniWire pressure guide wire

    185 cm

    Straight Tip

    OmniWire Pressure Guide Wire | Philips Healthcare (27)

    89185J

    OmniWire pressure guide wire

    185 cm

    J-Tip

    OmniWire Pressure Guide Wire | Philips Healthcare (28)

    Learn more about OmniWire

    OmniWire Pressure Guide Wire | Philips Healthcare (29)

    Let’s get connected

    #futureofIGT, #futureofCAD, #SolidCore #CoronaryIntervention

    How would you improve interventional procedures?

    What do you think about the new IntraSight platform?

    Are we on the right track?


    Connect with us via #futureofIGT /#OmniWire

    Media contacts:

    Fabienne van der Feer

    fabienne.van.der.feer@philips.com

    Phone: +31 622 698 001

    Mark Groves

    mark.groves@philips.com

    Phone: +31 631 639 916

    1. Data on file.:D000410086_A, D000485394_A

    2. Davies JE, et al., Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI. N Engl J Med. 2017 May 11;376(19):1824-1834.

    3. Gotberg M, et al., iFR-SWEDEHEART Investigators. Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCI. N Engl J Med. 2017 May 11;376(19):1813-1823.

    4. Comparisons to Verrata Plus. Data/report internally on file or internal company’s data on file. Verification Report, D000410086/A

    5. Patel M. “Cost-effectiveness of instantaneous wave-Free Ratio (iFR) compared with Fractional Flow Reserve (FFR) to guide coronary revascularization decisionmaking.” Late-breaking Clinical Trial presentation at ACC on March 10, 2018

    6. Patel M, et al., ACC/AATS/AHA/ASE/ASNC/SCAI/SCCT/STS 2017 Appropriate Use Criteria for Coronary Revascularization in Patients with Stable Ischemic Heart Disease. J Am Coll Cardiol. 2017 May 2;69(17):2212-2241.

    7. ACC CathPCI Hospital Registry.https://www.ncdr.com/WebNCDR/cathpci/home/datacollection.

    8. Lofti A, et al. Focused update of expert consensus statement: Use of invasive assessments of coronary physiology and structure: A position statement of the society of cardiac angiography and interventions. Catheter Cardiovasc Interv. 2018;1–12.

    9. 2018 ESC/EACTS Guidelines on myocardial revascularization: The task force on myocardial revascularization of the European society of cardiology (ESC) and European association for cardio-thoracic surgery (EACTS). Eur Heart J. 2018;00:1-96.

    10. Davies JE, et al., DEFINE-FLAIR: A Multi- Centre, Prospective, International, Randomized, Blinded Comparison of Clinical Outcomes and Cost Efficiencies of iFR and FFR Decision-Making for Physiological Guided Coronary Revascularization. New England Journal of Medicine, epub March 18, 2017.

    11. Gotberg M, et al., Instantaneous Wave-Free Ratio Versus Fractional Flow Reserve Guided Intervention (IFR-SWEDEHEART): A Multicenter, Prospective, Registry-Based Randomized Clinical Trial. New England Journal of Medicine, epub March 18, 2017.

    12. Patel M. “Cost-effectiveness of instantaneous wave-Free Ratio (iFR) compared with Fractional Flow Reserve (FFR) to guide coronary revascularization decision-making.” Late-breaking Clinical Trial presentation at ACC on March 10, 2018.

    ©2020 Koninklijke Philips N.V. All rights reserved. Approved for external distribution. D050514-00 052020

    By clicking on the link, you will be leaving the official Royal Philips ("Philips") website. Any links to third-party websites that may appear on this site are provided only for your convenience and in no way represent any affiliation or endorsem*nt of the information provided on those linked websites. Philips makes no representations or warranties of any kind with regard to any third-party websites or the information contained therein.

    I understand

    You are about to visit a Philips global content page

    Continue

    OmniWire Pressure Guide Wire | Philips Healthcare (2024)

    References

    Top Articles
    Latest Posts
    Article information

    Author: Ray Christiansen

    Last Updated:

    Views: 6648

    Rating: 4.9 / 5 (69 voted)

    Reviews: 92% of readers found this page helpful

    Author information

    Name: Ray Christiansen

    Birthday: 1998-05-04

    Address: Apt. 814 34339 Sauer Islands, Hirtheville, GA 02446-8771

    Phone: +337636892828

    Job: Lead Hospitality Designer

    Hobby: Urban exploration, Tai chi, Lockpicking, Fashion, Gunsmithing, Pottery, Geocaching

    Introduction: My name is Ray Christiansen, I am a fair, good, cute, gentle, vast, glamorous, excited person who loves writing and wants to share my knowledge and understanding with you.